Receivers Compatible with the Control Panel
Event Description
SBUS Class A supervision lost
SBUS Class A supervision restore
SBUS expander trouble
SBUS expander trouble restore
SLC class A supervision trouble
SLC class A supervision trouble restore
SLC programming ended, system active
SLC programming started, system shut
down
SLC short circuit trouble
SLC short circuit trouble restore
Time changed event
Unable to report to account trouble
Unable to report to account trouble restore
User access code changed
User initiated manual dialer test
Walk test begin
Walk test end
Zone Events
Auxiliary power trouble
Auxiliary power trouble restore
CO Detector Alarm
CO Detector Alarm Restore
CO Detector Supervisory Alarm
CO Detector Supervisory Alarm Restore
CO Detector Trouble
CO Detector Trouble Restore
Detector Alarm
Detector Alarm Restore
Detector trouble
Detector trouble restore
ECS Switch Trouble
ECS Switch Trouble Restore
ECS Supervisory/Tamper Alarm
ECS Supervisory/Tamper Alarm Restore
ECS Output Group Trouble
ECS Output Group Trouble Restore
External Reset/Silence/Fire Drill switch
trouble
External Reset/Silence/Fire Drill switch
trouble restore
IFP-300 Series Manual — P/N LS10145-001SK-E:C 4/6/2022
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter
ID #
Event
(If Any)
Code
s
ET
Exp. ID
ER
Exp. ID
ET
Exp. ID
ER
Exp. ID
ET
Exp. ID
ER
Exp. ID
TE
0
TS
0
ET
Exp. ID
ER
Exp. ID
JT
0
RT
Receiver #
YK
Receiver #
JV
0
RX
0
TS
0
TE
0
Zone events are reported only when "Report by Zone" is selected
FT
0000
FJ
0000
GA
Zone #
GH
Zone #
GS
Zone #
GR
Zone #
GT
Zone #
GJ
Zone #
FA
Zone #
FH
Zone #
FT
Zone #
FJ
Zone #
QT
0
QJ
0
QS
0
QR
0
QT
Group # +1000
QJ
Group # +1000
UT
0000
UJ
0000
Table 11.2 Report Formats Table (Continued)
Contact ID Reporting Format
SIA
Fixed Length
Qualifier Event
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
ETNNXX0000
1
ERNNXX0000
3
ETNNXX0000
1
ERNNXX0000
3
ETNNXX0000
1
ERNNXX0000
3
TENN000000
3
TSNN000000
1
ETNNXX0000
1
ERNNXX0000
3
JTNN000000
1
RTNN00RRRR
1
YKNN00RRRR
3
JVNN000000
1
RXNN000000
1
TSNN000000
1
TENN000000
3
FTNN000000
1
FJNN000000
3
GANN000ZZZ
1
GHNN000ZZZ
3
GSNN000ZZZ
1
GRNN000ZZZ
3
GTNN000ZZZ
1
GJNN000ZZZ
3
FANN000ZZZ
1
FHNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
QTNN000000
1
QJNN000000
3
QSNN000000
1
QRNN000000
3
QTNN001GGG
1
QJNN001GGG
3
UTNN000000
1
UJNN000000
3
Reporting
Group #
Contact #
Code
333
Exp. ID
000
333
Exp. ID
000
333
Exp. ID
000
333
Exp. ID
000
331
Exp. ID
000
331
Exp. ID
000
607
00
000
607
00
000
332
Exp. ID
000
332
Exp. ID
000
625
00
000
354
00
Receiver
#
354
00
Receiver
#
602
00
000
601
00
000
607
00
000
607
00
000
320
00
000
320
00
000
162
00
Zone #
162
00
Zone #
200
00
Zone #
200
00
Zone #
373
00
Zone #
373
00
Zone #
110
00
Zone #
110
00
Zone #
373
00
Zone #
373
00
Zone #
242
00
000
242
00
000
241
00
000
241
00
000
320
00
Group #
320
00
Group #
373
00
000
373
00
000
147