r0065

Slip frequency / f_Slip

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Hz]
Description:
Displays the slip frequency for induction motors (ASM).
r0066

CO: Output frequency / f_outp

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Hz]
Description:
Display and connector output for the output frequency of the Motor Module.
Dependency:
Refer to: r0024
Note:
The output frequency is available smoothed (r0024) and unsmoothed (r0066).
r0067

CO: Output current maximum / I_outp max

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Arms]
Description:
Display and connector output for the maximum output current of the power unit.
Dependency:
The maximum output current is determined by the parameterized current limit and the motor and converter thermal
protection.
Refer to: p0290, p0640
r0068

CO: DC current in the DC link / Idc DC link

B_INF
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the DC current in the DC link.
Dependency:
Refer to: r0027
Notice:
For Basic Line Modules of chassis format, the displayed value is invalid as these units do not have any current
sensing.
Note:
The DC current in the DC link is available smoothed (r0027) and unsmoothed (r0068).
62
Calculated: -
Dyn. index: -
Units group: 2_1
Scaling: p2000
Max
- [Hz]
Calculated: -
Dyn. index: -
Units group: 2_1
Scaling: p2000
Max
- [Hz]
Calculated: -
Dyn. index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Units group: 6_4
Scaling: p2002
Max
- [A]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 6310, 6700,
6727, 6730, 6732
Unit selection: p0505
Expert list: 1
Factory setting
- [Hz]
Access level: 3
Func. diagram: 5300, 5730,
6300, 6310, 6730, 6731, 6799
Unit selection: p0505
Expert list: 1
Factory setting
- [Hz]
Access level: 3
Func. diagram: 5722, 6300,
6301, 6640
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: 8014, 8750
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
SINAMICS G130/G150