p4111[0...2]

TM150 group channel assignment / TM150 grp channel

TM150
Can be changed: T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Assigns the temperature channels to groups for the Terminal Module 150 (TM150)
For each group, the following calculated values are provided from the temperature actual values (r4105[0...11]):
- Maximum value (r4112[0...2])
- Minimum value (r4113[0...2])
- average value (r4114[0...2])
Index:
[0] = Group 0
[1] = Group 1
[2] = Group 2
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
Dependency:
Refer to: r4105, r4112, r4113, r4114
Notice:
When forming groups, it must be ensured that in one particular group, only temperature channels with the following
sensor types are included:
- "KTY84", "PT100", "PT1000" (p4100[0...11] = 2, 5, 6), real temperature actual value
or alternatively
- "PTC thermistor", "bimetallic NC contact" (p4100[0...11] = 1, 4), fictitious temperature actual value (-50 °C, 250 °C)
If these sensor types are combined within one group, then the calculated values for maximum, minimum and average
value will be falsified.
Note:
Active and inactive temperature channels can be included in one group. However, when calculating the values
(r4112, r4113, r4114) only the active temperature channels with valid actual value are taken into account
(r4105[0...11] not equal to -300 °C).
r4112[0...2]
CO: TM150 group temperature actual value maximum value / TM150 grp temp max
TM150
Can be changed: -
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
- [°C]
Description:
Display and connector output for the maximum value of each group for the Terminal Module 150 (TM150).
This value is calculated from the actual temperature values (r4105[0...11]) of each group.
Recommend.:
The following connector inputs can use these connector outputs for interconnection:
- CI: p0603
- CI: p0608[0...3]
- CI: p0609[0...3]
- CI: p2051
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Temperature channel 0
Temperature channel 1
Temperature channel 2
Temperature channel 3
Temperature channel 4
Temperature channel 5
Temperature channel 6
Temperature channel 7
Temperature channel 8
Temperature channel 9
Temperature channel 10
Temperature channel 11
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2006
Max
- [°C]
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 9625
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 1
Func. diagram: 9625
Unit selection: -
Expert list: 1
Factory setting
- [°C]