2 Parameters
2.2 List of parameters
p0453[0...n]

Pulse encoder evaluation zero speed measuring time / Enc_ev n_0 t_meas

ENC, VECTOR_G
Can be changed: C2(4)
Data type: FloatingPoint32
P-Group: Encoder
Not for motor type: -
Min
0.10 [ms]
Description:
Sets the measuring time for evaluating zero speed.
If no pulses are detected from track A/B during this time, a speed actual value of zero is output.
Dependency:
Refer to: r0452
Note:
This function is required for slow-running motors so that actual speeds close to zero can be output correctly.
r0455

Encoder configuration recognized / Enc config act

ENC
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the detected encoder configuration.
In this case, the encoder must automatically support the function (e.g. encoder with EnDat interface).
Bit field:
Bit
00
01
02
03
04
05
06
08
09
10
11
12
13
14
15
16
17
20
21
22
23
Dependency:
Refer to: p0404
Note:
ZM: Zero mark
This parameter is only used for diagnostics.
A value of zero is displayed if an encoder is not present.
Re bit 20, 21 (voltage level 5 V, voltage level 24 V):
The voltage level cannot be detected. Therefore, these bits are always set to 0.
172
Signal name
Linear encoder
Absolute encoder
Multiturn encoder
Track A/B sq-wave
Track A/B sine
Track C/D
Hall sensor
EnDat encoder
SSI encoder
DRIVE-CLiQ encoder
Digital encoder
Equidistant zero mark
Irregular zero mark
Distance-coded zero mark
Commutation with zero mark (not ASM)
Acceleration
Track A/B analog
Voltage level 5 V
Voltage level 24 V
Remote sense (only SMC30)
Resolver excit
Calculated: -
Dyn. index: EDS, p0140
Units group: -
Scaling: -
Max
10000.00 [ms]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1000.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No