Co: Output Signal Wordwise 3 / Outp_Sig Word 3; Aop Local/Remote / Aop Local/Remote - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r8515

CO: Output signal wordwise 3 / Outp_sig word 3

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signal interconnected via connector input p8505.
Dependency:
Refer to: p8505
p8550

AOP LOCAL/REMOTE / AOP LOCAL/REMOTE

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Setting for saving the actual configuration of the Advanced Operator Panel (AOP).
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
14
15
r8570[0...39]
Macro drive object / Macro DO
B_INF, CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: -
CU_G150_PN,
Not for motor type: -
TM150, TM31,
VECTOR_G
Min
-
Description:
Displays the macro file saved in the appropriate directory on the memory card/device memory.
Dependency:
Refer to: p0015
Note:
For a value = 9999999, the following applies: The read operation is still running.
r8571[0...39]
Macro Binector Input (BI) / Macro BI
B_INF, VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p0700
Note:
For a value = 9999999, the following applies: The read operation is still running.
750
Signal name
LOCAL save
Start in LOCAL
Change in oper
OFF acts like OFF1
OFF acts like OFF2
OFF acts like OFF3
Reserved
CW/CCW active
Jog active
Save speed setpoint
Inhibit operation
Inhibit parameterization
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 2
Func. diagram: 2195
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 1001 bin
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
SINAMICS G130/G150
FP
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents