Value:
0:
1:
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Dependency:
The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
p4097[0...1]

TM31 analog inputs simulation mode / TM31 AI sim_mode

TM31
Can be changed: U, T
Data type: Integer16
P-Group: Terminals
Not for motor type: -
Min
0
Description:
Sets the simulation mode for the analog inputs of Terminal Module 31 (TM31).
Value:
0:
1:
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency:
The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
p4098[0...1]

TB30 analog inputs simulation mode setpoint / TB30 AI sim setp

TB30
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
-11.000 [V]
Description:
Sets the setpoint for the input voltage in the simulation mode of the analog inputs of Terminal Board 30 (TB30).
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Dependency:
The simulation of an analog input is selected using p4097.
Refer to: p4097
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
p4098[0...1]

TM31 analog inputs simulation mode setpoint / TM31 AI sim setp

TM31
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
-20.000
Description:
Sets the setpoint for the input value in simulation mode of the analog inputs of Terminal Module 31 (TM31).
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Terminal evaluation for analog input x
Simulation for analog input x
Terminal evaluation for analog input x
Simulation for analog input x
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
11.000 [V]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
20.000
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 9566, 9568
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 9104
Unit selection: -
Expert list: 1
Factory setting
0.000 [V]
Access level: 2
Func. diagram: 9566, 9568
Unit selection: -
Expert list: 1
Factory setting
0.000