2 Parameters
2.2 List of parameters
5:
6:
Dependency:
The functions in p9938 can only be set for p9937.0 = 0.
Refer to: r9936, p9937, p9939, p9942
Notice:
If value = 0:
- detailed diagnostics is inactive.
- the error counter is active (r9936).
If value > 0:
- the error counter is inactive (r9936).
- the detailed diagnostics as configured is active (r9943).
p9939

DRIVE-CLiQ detailed diagnostics time interval / DQ detail t_interv

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
1 [s]
Description:
Sets the time interval for recording the error counter in r9943.
Dependency:
Refer to: r9936, p9938, p9942, r9943
p9941

Target topology feature delete all components / Feature delete

CU_G130_DP,
Can be changed: C1(1)
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
0
Description:
For p9941 =1, the serial numbers of all components in the target topology are deleted (zero is written).
Through activation and de-activation this enables the actual topology components to be newly assigned to the target
topology components.
Note:
p9941 is automatically set to 0 at the end of the operation.
A warm restart is triggered automatically after p0009 = 0.
p9942
DRIVE-CLiQ detailed diagnostics select individual connection / DQ detail conn
CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the component, whose feeder cable is monitored for data transfer errors.
The feeder cable is the DRIVE-CLiQ cable that is connected to a component in the direction of the Control Unit.
Errors that have occurred in the selected time interval (p9939) can be read-out from r9943.
Dependency:
Refer to: r9936, p9938, p9939, r9943
958
Siemens internal
Siemens internal
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
3600 [s]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
199
List Manual (LH2), 04/2014, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1 [s]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0