2 Parameters
2.2 List of parameters
4:
5:
6:
7:
8:
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0489, p0728
Notice:
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CX32, NX10 and NX15, only DI/DO 8, 9, 10, 11 can be selected as fast inputs (refer to the Equipment Manual).
Note:
DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
p0489
Measuring probe 2 input terminal / Meas probe 2 inp
ENC
Can be changed: U, T
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal to connect probe 2.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
Dependency:
Refer to: p0488, p0728
Notice:
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CX32, NX10 and NX15, only DI/DO 8, 9, 10, 11 can be selected as fast inputs (refer to the Equipment Manual).
Note:
DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
p0489[0...2]
Measuring probe 2 input terminal / Meas probe 2 inp
VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal to connect probe 2.
Value:
0:
1:
2:
3:
196
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI/DO 8 (X122.9/X121.7)
DI/DO 12 (X132.9/X131.1)
No meas probe
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI/DO 8 (X122.9/X121.7)
DI/DO 12 (X132.9/X131.1)
No meas probe
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
8
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0