Figure 86
Right-Boom Section Shown
1. Supply hose—right boom
2 x 170 cm (3/4 x 66-13/16
inches)
2. Hose clamp
4. Assemble the center boom-supply hose onto the
T-fitting at the right-boom section
5. Secure the hose to the T-fitting with a hose clamp that
you removed in
Removing the Boom-Section Hoses
(page
20).
6. Repeat steps
3
through
at the left-boom section.
3. T-fitting
4. Support clamp
(Figure
86).
5
for the left boom-supply hose
15
Installing the Shutoff Valve and
Hose for the Optional Spray
Gun Kit or Electric Hose-Reel
Kit
Parts needed for this procedure:
1
Flange shutoff valve
1
Bracket (nylon)
1
90° elbow (with pressure port)
1
Gasket—25 x 35 mm (1 x 1-3/8 inches)
1
Flange clamp—40 to 64 mm (1-9/16 to 2-1/2 inches)
4
Washer (5/16 x 13/16 inch)
4
Bolt (6 x 16 mm)
2
Hose clamp
1
Quick-connect fitting (socket)
1
Straight barbed fitting (1/2 inch)
1
Hose—1.3 x 762 cm (1/2 x 300 inches)
1
Hose—1.3 x 180 cm (1/2 x 71 inches)
3
Cable ties
Preparing the Shutoff Valve
1. If not assembled, insert the 4 stainless steel nuts into
the slots in the nylon bracket for the flange shutoff
valve
(Figure
87).
1. Nylon bracket
2. Stainless steel nut
3. Flange shutoff valve
39
Figure 87
4. Retainer
5. Straight barbed fitting (3/4
inch)
6. Screw (6-32 x 5/8 inch)

Advertisement