Group 09 System Info - ABB ACSM1 Firmware Manual

Motion control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

Group
08 ALARMS & FAULTS
Signals containing alarm and fault information.
08
08 ALARMS & FAULTS
8.01
ACTIVE FAULT
Fault code of the latest (active) fault.
8.02
LAST FAULT
Fault code of the 2nd latest fault.
8.03
FAULT TIME HI
Time (real time or power-on time) at which the active fault occurred in format dd.mm.yy
(=day.month.year).
8.04
FAULT TIME LO
Time (real time or power-on time) at which the active fault occurred in format hh.mm.ss
(hours.minutes.seconds).
8.05
ALARM WORD 1
Alarm word 1. For possible causes and remedies, see chapter
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FW block:
FW block:
FW block:
FW block:
FW block:
Alarm
BRAKE START TORQUE
BRAKE NOT CLOSED
BRAKE NOT OPEN
SAFE TORQUE OFF
STO MODE CHANGE
MOTOR TEMPERATURE
EMERGENCY OFF
RUN ENABLE
ID-RUN
EMERGENCY STOP
POSITION SCALING
BR OVERHEAT
BC OVERHEAT
DEVICE OVERTEMP
INTBOARD OVERTEMP
BC MOD OVERTEMP
FAULT FUNCTIONS
(page 173)
FAULT FUNCTIONS
(page 173)
FAULT FUNCTIONS
(page 173)
FAULT FUNCTIONS
(page 173)
FAULT FUNCTIONS
(page 173)
Fault
Parameters and firmware blocks
tracing.
99

Advertisement

Table of Contents
loading