Dynamic Position Reference Limiter - ABB ACSM1 Firmware Manual

Motion control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

One reference set is used at a time. The definition and selection of position
reference sets are done using the parameters in

Dynamic position reference limiter

The dynamic limiter controls the position reference limitation in position control and
synchron control modes. Dynamic limitation of the position reference causes
a synchron error
position profile generator.
Start/stop examples with dynamic limiter
The speed curves of the master and follower during the start and stop are presented
in the figures below.
When the follower is in synchron control, the reference can be taken from the
encoder or from another drive. The master can be in any control mode.
Start: linear axis, relative synchronisation
Used when the master is to be distance C ahead of the
follower at start.
60.02 POS AXIS MODE
SYNCHRON MODE
is set to
To catch the master position, the follower accelerates
up to its maximum allowed speed. Only master position
changes which take place after the follower is started
are taken into account.
Start: linear axis, absolute synchronisation
Used when the master and the follower are to be driven
equal distances.
60.02 POS AXIS MODE
SYNCHRON MODE
is set
To catch the master position, the follower accelerates
up to its maximum allowed speed. Master position
changes which take place before and after the follower
is started are taken into account.
Start: rollover axis
60.02 POS AXIS MODE
The follower accelerates until it has reached the master
shaft position angle (position per one revolution,
0...360
. Rotations of the master are not counted.
°)
(4.18 SYNC
is set to
(0)
LINEAR.
68.07
(1)
RELATIVE.
is set to
(0)
LINEAR.
68.07
(0)
ABSOLUTE.
is set to
(1)
ROLLOVER.
Group 65 PROFILE
ERROR). The error is accumulated and fed back to the
Speed
70.04 POS SPEED LIM
Master speed
A
70.05 POS ACCEL LIM
C
Follower speed
Speed
70.04 POS SPEED LIM
Master speed
70.05 POS ACCEL LIM
A
Follower speed
Speed
70.04 POS SPEED LIM
70.05 POS ACCEL LIM
Follower speed
REFERENCE.
A = B
70.06 POS DECEL LIM
B
Synchronised
A = B
70.06 POS DECEL LIM
B
70.06 POS DECEL LIM
Synchronised
Master speed
Drive control and features
55
t
t
t