232
(4) 500 kbit/s
(5) 1000 kbit/s
91.25 SSI MODE
Selects the SSI encoder mode.
Note: Parameter needs to be set only when an SSI encoder is used in continuous mode, i.e. SSI
encoder without incremental sin/cos signals (supported only as encoder 1). SSI encoder is selected
by setting parameter
(0) INITIAL POS.
(1) CONTINUOUS
91.26 SSI TRANSMIT CYC
Selects the transmission cycle for SSI encoder.
Note: This parameter needs to be set only when an SSI encoder is used in continuous mode, i.e. SSI
encoder without incremental sin/cos signals (supported only as encoder 1). SSI encoder is selected
by setting parameter
(0) 50 us
(1) 100 us
(2) 200 us
(3) 500 us
(4) 1 ms
(5) 2 ms
91.27 SSI ZERO PHASE
Defines the phase angle within one sine/cosine signal period that corresponds to the value of zero on
the SSI serial link data. The parameter is used to adjust the synchronization of the SSI position data
and the position based on sine/cosine incremental signals. Incorrect synchronization may cause an
error of ±1 incremental period.
Note: This parameter needs to be set only when an SSI encoder with sine/cosine incremental signals
is used in initial position mode.
(0) 315–45 DEG
(1) 45–135 DEG
(2) 135–225 DEG
(3) 225–315 DEG
91.30 ENDAT MODE
Selects the EnDat encoder mode.
Note: This parameter needs to be set only when an EnDat encoder is used in continuous mode, i.e.
EnDat encoder without incremental sin/cos signals (supported only as encoder 1). EnDat encoder is
selected by setting parameter
(0) INITIAL POS.
Parameters and firmware blocks
500 kbit/s.
1000 kbit/s.
FW block:
ABSOL ENC CONF
91.02 ABS ENC INTERF
Single position transfer mode (initial position).
Continuous position transfer mode.
FW block:
ABSOL ENC CONF
91.02 ABS ENC INTERF
50 µs.
100 µs.
200 µs.
500 µs.
1 ms.
2 ms.
FW block:
ABSOL ENC CONF
315–45 degrees.
45–135 degrees.
135–225 degrees.
225–315 degrees.
FW block:
ABSOL ENC CONF
91.02 ABS ENC INTERF
Single position transfer mode (initial position).
(see above)
to
(4)
SSI.
(see above)
to
(4)
SSI.
(see above)
(see above)
to
(2)
ENDAT.