• Invert the phases by changing the value of
parameter
9914
to 1 (YES), or vice versa.
• Verify your work by applying input power and
repeating the check as described above.
SPEED LIMITS AND ACCELERATION/DECELERATION TIMES
Set the minimum speed (parameter 2001).
Set the maximum speed (parameter 2002).
Set the acceleration time 1 (parameter 2202).
Note: Set also acceleration time 2 (parameter
2205) if two acceleration times will be used in the
application.
Set the deceleration time 1 (parameter 2203).
Note: Set also deceleration time 2 (parameter
2206) if two deceleration times will be used in the
application.
SAVING A USER MACRO AND FINAL CHECK
The start-up is now completed. However, it might
be useful at this stage to set the parameters
required by your application and save the settings
as a user macro as instructed in section
macros
on page 119.
Check that the drive state is OK.
Basic control panel: Check that there are no faults
or alarms shown on the display.
If you want to check the LEDs on the front of the
drive, switch first to remote control (otherwise a
fault is generated) before removing the panel and
verifying that the red LED is not lit and the green
LED is lit but not blinking.
Assistant control panel: Check that there are no
faults or alarms shown on the display and that the
panel LED is green and does not blink.
to the opposite, ie from 0 (NO)
The drive is now ready for use.
Start-up, control with I/O and ID run 65
LOC
LOC
LOC
LOC
LOC
LOC
User
9914
PAR
FWD
2001
PAR
FWD
2002
PAR
FWD
2202
PAR
FWD
2203
PAR
FWD
9902
PAR
FWD

Hide quick links: