ABB ACS355 User Manual page 201

Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

All parameters
No.
Name/Value
TIMED FUNC 3 Timed function 3 is active. See parameter group
TIMED FUNC 4 Timed function 4 is active. See parameter group
M.TRIG FAN
M.TRIG REV
M.TRIG RUN
M.TRIG MWH
SEQ PROG
MBRK
JOG ACTIVE
STO
STO(-1)
1402 RELAY
OUTPUT 2
1403 RELAY
OUTPUT 3
1404 RO 1 ON
DELAY
0.0...3600.0 s
1405 RO 1 OFF
DELAY
0.0...3600.0 s
Description
FUNCTIONS.
FUNCTIONS.
Cooling fan running time counter is triggered. See
parameter group
29 MAINTENANCE
Revolutions counter is triggered. See parameter group
MAINTENANCE
TRIG.
Run time counter is triggered. See parameter group
MAINTENANCE
TRIG.
MWh counter is triggered. See parameter group
MAINTENANCE
TRIG.
Relay output control with Sequence programming. See
parameter
8423 ST1 OUT
On/Off control of a mechanical brake. See parameter group
43 MECH BRK
CONTROL.
Jogging function active. See parameter
SEL.
STO (Safe torque off) has been triggered.
STO (Safe torque off) is inactive and the drive operates
normally.
See parameter
1401 RELAY OUTPUT
the MREL-01 relay output extension module is connected to
the drive.
See parameter
1401 RELAY OUTPUT
the MREL-01 relay output extension module is connected to
the drive.
Defines the operation delay for relay output RO 1.
Delay time. The figure below illustrates the operation (on)
and release (off) delays for relay output RO.
Control event
Relay status
1404
Defines the release delay for relay output RO 1.
Delay time. See the figure for parameter
DELAY.
Actual signals and parameters 201
TRIG.
CONTROL.
1010 JOGGING
1. Available only if
1. Available only if
On delay
1405
1404 RO 1 ON
Def/FbEq
36 TIMED
39
36 TIMED
40
41
29
42
29
43
29
44
50
51
52
57
58
NOT SEL
NOT SEL
0.0 s
1 = 0.1 s
Off delay
0.0 s
1 = 0.1 s