Programming A Privacy Zone; Changing The Privacy Zone Mask Color; Assigning Or Editing Privacy Zone Priority Order; Table 5-6 Privacy Zone Functions - Honeywell ACUIX Installation And Configuration Manual

Ptz high speed analog dome camera
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

Task/Action (with Default)

Programming a Privacy Zone

1.
Position the dome so the area to be covered by the privacy
zone is on the monitor.
2.
Select 6 Function Programming
3.
Enter the 4 digit PIN. The default is 1000.
4.
Select a privacy zone number between 1 and 24 to assign the
area. Privacy zones are assigned a priority between 1 and 24 in
the order programmed. For example, if user programs Zone 24
before Zone15, Zone 24 is a Priority 1 and Zone 15 is a
Priority 2.
If a privacy zone is disabled, it does not display on the PTZ
Priority Menu.
When a privacy zone is enabled, it is assigned the highest
unused priority available.
5.
Press Focus Far (-) to switch to PTZ mode to gain control over
the joystick. Adjust the coordinates of the privacy zone as
required using the joystick and moving it up or right to create a
mask/box.
The tilt cannot be greater than 70 and the zoom cannot be
more than 1x.
6.
Press Focus Near (+) to switch to menu mode to access the
controller keyboard. Press Iris Open (+) to save the
coordinates.
7.
Program another privacy zone or exit.

Changing the Privacy Zone Mask Color

1.
Select 6 Function Programming
3 Privacy Zone Color.
2.
Select the color of the mask, Black, Blur or White.

Assigning or Editing Privacy Zone Priority Order

1.
Select 6 Function Programming
1 Change Priv Zone Priority.
2.
From the Zone Name or Zone ID columns, select a privacy
zone to edit and assign a different priority number.
Priority 1 has the highest priority and Priority 24
the lowest no matter the privacy zone number assigned.
That is to say, there is no relation between zone id and
zone priority.
3.
In the From field, enter the current priority number, for example,
4.
4.
In the To field, enter the new priority number, for example, 1.
Document 800-05662 Rev C
06/10
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Table 5-6
Privacy Zone Functions
6 Program Privacy Zone.
3 Privacy Zone Options
3 Privacy Zone Options
Notes
This menu is available only when using
MAXPRO-mode, VCL, UTP and Pelco P or
D protocols.
This menu is available only when using
MAXPRO-mode, VCL, UTP and Pelco P or
D protocols.
The priority order is useful if privacy zones
overlap.
This menu is only available in
MAXPRO-mode, VCL, UTP and Pelco P or
D protocols.
CHANGE PRIV ZONE PRIORITY
PRIORITY PZ_NAME
1 Privacy 1
2 Privacy 2
3 Privacy 3
Change Priority _-- to --
ZONE
ID
-
1
2
3
103