Changing the Address, Protocol, Parity or Baud Rate Using the OSD

Sending Common Commands to all Domes

Document 800-05662 Rev C
06/10
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Caution
Changing these settings can cause loss of communication between the
controller and the dome. Do not go above the limit of the controller as this
Access to the OSD Is determined by the DIP switch SW5-8 setting. If this
switch is set to OFF, the current address and protocol settings can be
viewed but not changed.
1.
Select 75
Preset
1 Change Dome (Camera) address
2 Change Protocol
3 Change Baud Rate
4 Change Parity
2.
Select the applicable settings:
Enter a numerical dome address.
Select a protocol: Diamond, MAXPRO-mode, VCL-485, VCL UTC, Pelco P,
Pelco D, IntelliBus.
Select a baud rate: 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or
115200.
Select a parity: Even, Odd, or None.
Caution
Only enable the Broadcast Command mode when common settings
require changing and these common settings are for the same value
across the network. Otherwise the dome performs all the commands even
if not required or sent to that dome.
Special presets 73 and 74 enable and disable the broadcast command receive mode.
When enabled, all domes receive all the commands sent from the controller to any dome
address. For example, an operator might want to standardize the on-screen display (OSD)
language displayed on the monitors for all the domes in the system.
Note
This option is not applicable to IntelliBus protocol as this protocol uses a
different addressing mechanism to communicate with domes.
111