Table 3-2 Typical Dip Switch Settings By Protocol - Honeywell ACUIX Installation And Configuration Manual

Ptz high speed analog dome camera
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

Protocol
Baud and Parity
Description
Intellibus™
38400 baud, no parity
MAXPRO*
9600 baud, even parity*
VCL - RS485
9600 baud, no parity
VCL UTC
9600 baud, no parity
Diamond
9600 baud, even parity
Pelco P
4800 baud, no parity
(default for P-type control)
Pelco D
2400 baud, no parity
(default for D-type control)
Pelco P_AD
4800 baud, no parity
default for P-type control
Pelco D_AD
2400 baud, no parity
default for D-type control
* defaults
Document 800-05662 Rev C
06/10
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Table 3-2
Typical DIP Switch Settings by Protocol
SW6 - Baud and Parity Settings
1
2
3
4
OFF ON
ON
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
OFF OFF ON
OFF ON
OFF OFF ON
OFF OFF OFF OFF OFF ON
OFF OFF ON
OFF OFF OFF OFF OFF OFF OFF ON
OFF OFF ON
OFF ON
ON
ON
OFF OFF OFF OFF OFF OFF ON
OFF ON
OFF OFF OFF OFF OFF OFF OFF ON
ON
ON
OFF OFF OFF OFF OFF OFF ON
OFF ON
OFF OFF OFF OFF OFF OFF OFF ON
5
6
7
8
1
2
OFF OFF OFF OFF ON
ON
OFF OFF OFF ON
OFF OFF OFF OFF OFF OFF ON
OFF ON
OFF ON
SW5 - Protocol Settings
3
4
5
6
7
8
OFF OFF OFF OFF OFF ON
OFF OFF OFF OFF OFF ON
OFF OFF OFF OFF ON
OFF OFF OFF OFF ON
ON
OFF OFF OFF OFF ON
OFF ON
OFF OFF ON
ON
OFF ON
OFF OFF ON
35

Hide quick links: