Handling and Cleaning the Scan Assembly and Lens

Handling and Cleaning the Lower Dome

Document 800-05662 Rev C
06/10
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
WARNING!
To avoid damage to the static sensitive receiver and power
supply boards, leave the scan assembly inside the pink,
static dissipating bag it was shipped in until the time of
installation.
If the unit is shipped anywhere at a later date, it must be
shipped in the pink bag or an equivalent static dissipating
enclosure.
Caution
Do not remove the camera from the scan assembly.
Do not touch the lens surface. Handle the camera lens with extreme care
A dirty lens surface due to dust, oil or fingerprints causes harmful flare that can result in
degenerating lens property. To clean the lens:
1.
Remove dust—Brush with an oil-free soft brush or a blower-brush (for photography
use).
2.
Remove water or oil—Wipe and dry the lens surface with a clean soft cloth. Prepare a
washed-out cotton cloth or lens cleaning paper with alcohol or lens cleaning liquid.
Clean by moving spirally from the lens center towards its rim. Repeat until completely
clean.
It is extremely important to treat the surface of all domes with the same care as you would
a fine camera lens.
Always handle the dome from the outer surface. Both the inside and outside can be
irreparably damaged if dropped or scratched.
To prevent scratching, carefully remove particles by hand (such as sand or grit) prior
to wiping or cleaning with a soft cloth.
After larger particles (such as the sand or grit) are removed by hand, use tepid water
and a cloth to wash units.
113