Installation
DIP Switch Default Settings and Locations
Setting
RS485 Termination
Video Selection Switch
Baud rate
Parity
Protocol
Address
Miscellaneous Defaults*
Reserved
Restore Factory Defaults
Overriding the Logical
Address
Debugging/boot control
* These are advanced switch settings and it is not recommended to make changes to these defaults. See the
System Administration and Equipment Handling
34
Caution
•
To make good wire contact and ensure the wire does not short to
adjacent wires, fully insert the wire in the hole on the terminal strip.
•
A good earth ground must be connected at J1, pin 2. Surge
suppression is not provided if the unit is not connected to a good earth
ground.
•
Ensure there are no bare wires touching or faulty operation may occur.
•
Ensure the cabling does not interfere with the rotation of the scan
assembly.
•
To maintain 24 VAC ± 10% at each dome, the proper wire size for the
distance and the number of domes must be determined.
•
For CE compliance, the power supply must be connected to a CE
approved 240V UPS (uninterruptible power supply). See
Preparation
FCC and UL requirements.
Table 3-1
Default DIP Switch Settings
Default
Not terminated
OFF
9600
Even
MAXPRO-mode
1
OFF
OFF
ON
OFF
for more information.
for a list of the power supplies which must be used to meet
Switch and Available
Positions
SW1
SW2
SW6, positions 1 to 4
SW6, positions 5 and 6
SW5, positions 1 to 5
SW1, SW2, SW3 and SW4
SW6-8
SW5-7
SW5-8
SW6-7
Installation
Switch Location
Housing Interface
Board
Housing Interface
Board
Circuit Board
Circuit Board
Circuit Board
Circuit Board
Circuit Board
Circuit Board
Circuit Board
Circuit Board