Example Call Progress Tone Parameters

Example Call Progress Tone Parameters
Cisco ATA 186 Installation and Configuration Guide
F-4
Table F-1
Volume Levels for a Standard U.S. 600-Ohm Impedance Board
Volume Level for One Tone Volume Level for Two Tones
Scale Factor (A)
Component (dBm)
0.10
-24
0.175
-19
0.35
-13
0.50
-10
U.S. Values are:
RingOnOffTime: 2,4,25
DialTone: 2,31538,30831,3100,3885,1,0,0,1000
BusyTone: 2,30467,28959,1191,1513,0,4000,4000,0
ReorderTone: 2,30467,28959,1191,1513,0,2000,2000,0
RingBackTone: 2,30831,30467,1943,2111,0,16000,32000,0
CallWaitTone: 1,30831,0,5493,0,0,2400,2400,4800
AlertTone: 1,30467,0,5970,0,0,480,480,1920
Swedish values are:
RingOnOffTime: 1,5,25
DialTone: 1,30959,0,4253,0,1,0,0,1500
BusyTone: 1,30959,0,2392,0,0,2000,2000,0
ReorderTone: 1,30959,0,2392,0,0,2000,6000,0
RingBackTone: 1,30959,0,2392,0,0,8000,40000,0
CallWaitTone: 1,30959,0,2392,0,0,1600,4000,11200
AlertTone: 1,30959,0,2392,0,0,2000,6000,0
Appendix F
Call Progress Tone Parameters and Defaults
Components (dBm)
-21
-16
-10
-7