Appendix B
Parameters and Defaults
Table B-3
Common Operating Parameters and Defaults (continued)
Parameter
Polarity
PWD0, PWD1
RxCodec
OL-1267-01
Value
Type
Description
Bitmap
Control connect and disconnect
polarity. Possible values are:
•
bit 0 (mask 0x1):
CALLER_CONNECT_
POLARITY
bit 1 (mask 0x2):
•
CALLER_DISCONNECT_
POLARITY
•
bit 2 (mask 0x4):
CALLEE_CONNECT_
POLARITY
bit 3 (mask 0x8):
•
CALLEE_DISCONNECT_
POLARITY
Alpha-
Password for line 0 and 1.
numeric
string
Integer
Receiving audio codec preference.
Possible values are:
0—G.723 (can be selected only if
•
LBRCodec is set to 0).
1—711a.
•
2—G.711u.
•
•
3—729a (can be selected only if
LBRCodec is set to 3).
Cisco ATA 186 Installation and Configuration Guide
Operating Parameters
IVR Access
Code
Default
304
0x00000000
PWD0=4
0
PWD1=14
36
0
B-13