Power Supply Leds - Cisco Nexus 7000 Series Hardware Installation And Reference Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Chassis and Module LEDs
Table 67: Fabric Module LEDs
LED
Status
Status
Green
Red
Flashing red
ID
Flashing blue
Off

Power Supply LEDs

Table 68: Power Supply LEDs , on page 249
ID LEDs have the same function for the AC, DC and HVAC/HVDC power supply units.
Table 68: Power Supply LEDs
LED
Input 1
Input 2 (available only on DC
power supply units)
Description
All diagnostics pass. The module is operational (normal initialization
sequence).
The diagnostic test has failed. The module is not operational because
a fault has occurred during the initialization sequence.
or
The inlet air temperature of the system has exceeded the safe
operating temperature limits of the card (a major environmental
warning). The card has been shut down to prevent permanent damage.
The fabric module has just been inserted and is booting up.
or
An overtemperature condition has occurred and the module has
powered down.
or
The power was turned off with a CLI command.
or
The module is resetting and both ejector levers are out.
The operator has activated this LED to identify this module in the
chassis.
This module is not being identified.
describes the power supply unit LEDs. The Output, Fault, and
Color
Green
Off
Green
Cisco Nexus 7000 Series Hardware Installation and Reference Guide

Power Supply LEDs

Condition
The AC, HVAC/HVDC or DC input voltage
is within the valid range.
The AC, HVAC/HVDC or DC input voltage
is outside the valid range.
The DC input voltage is within the valid
range.
249