First-Time Setup
If the input image is displaying correctly, you should see an image projected on the projection surface.
If the image is out of focus or is too small, use the projector focus ring to focus the image and use the
Step 9
zoom lever to create the largest possible image.
Click Stop in Cisco TelePresence System Administration to remove the test pattern and complete the
Step 10
projector test.

Projector Setup for Systems Without an Auxiliary Control Unit

To set up a projector for a CTS 3000 system that does not use an auxiliary control unit, complete the
following steps:
Start a test pattern display for the projector by completing the following steps:
Step 1
a.
b.
If you need to obtain the IP address, complete the following steps:
Note
Note
c.
d.
e.
f.
Turn on the projector by turning the projector power/rocker switch to the ON position.
Step 2
The projector takes approximately 15-30 seconds to warm up, and should be fully initialized within one
minute. If the projector is not receiving video, the screen will be blue. If the projector does not receive
video for five minutes and 30 seconds, the projector turns off.
The image is upside down and reversed since the projector is mounted upside down under the table.
Note
If the test pattern is displaying correctly, you should see a grid projected on the projection surface. In
the center of the grid, you should see a series of horizontal grey bars. You should also see a one-pixel
wide green border around the outside of the grid.
OL-14521-01
Click the VGA radio button to test input from a VGA device
Click the Document camera radio button to test input from the document camera
Open a browser that is connected to the network.
Enter the IP address of the primary codec to log in to Cisco TelePresence System Administration.
On the IP phone, locate Manual at the bottom of the screen and press the Manual soft key.
1.
If you cannot locate the Manual button, proceed to Step
2.
Locate Info at the bottom of the screen and press the Info soft key.
3.
Scroll down to the IP Address listing and copy the address.
Log in to the system by entering the following information:
Username: admin (case sensitive)
Password: cisco (case sensitive)
Select Troubleshooting > Hardware Setup, then click the Presentation Devices radio button.
Select the Test Pattern radio button.
Click Start to begin the test.