Chapter 1
Install the Shelf and Backplane Cable
Figure 1-17 Installing the AEP Cover
Insert and tighten the eight screws to secure the AEP cover to the AEP.
Step 2
Connect the cables from the external wire-wrap panel to the AMP Champ connectors on the AEP.
Step 3
Table 1-5 on page 1-41
output pin assignments.
input and output connectors, respectively.
Table 1-5
AMP Champ Pin
1
2
3
4
5
6
7
8
9
10
11
March 2003
lists the alarm input pin assignments.
Figure 1-18 on page 1-43
Alarm Input Pin Assignments
Signal Name
ALARM_IN_1-
GND
ALARM_IN_3-
ALARM_IN_5-
GND
ALARM_IN_7-
ALARM_IN_9-
GND
ALARM_IN_11-
ALARM_IN_13-
GND
NTP-A120 Install an External Wire-Wrap Panel to the AEP
Table 1-6 on page 1-42
and
Figure 1-19 on page 1-44
AMP Champ Pin Signal Name
27
GND
28
ALARM_IN_2-
29
ALARM_IN_4-
30
GND
31
ALARM_IN_6-
32
ALARM_IN_8-
33
GND
34
ALARM_IN_10-
35
ALARM_IN_12-
36
GND
37
ALARM_IN_14-
Cisco ONS 15454 Procedure Guide, R4.0
lists the alarm
illustrate the alarm
1-41