Host Ack On/Off; Host Ack Timeout; Host Ack Responses - Honeywell ORBIT 7120PLUS User Manual

Hybrid presentation scanner
Table of Contents

Advertisement

When a bar code is scanned, the scanner enters a timeout period until either the
host ACK sequence is received, or the timeout expires (in 10 seconds, by default).
Once Host ACK is enabled, the system works as follows when a bar code is
scanned:
A time-out occurs if the scanner does not receive a valid escape command within
10 seconds. A time-out is indicated by an error tone. If a time-out occurs, the oper-
ator should check the host system to understand why a response to the scanner
was not received.

Host ACK On/Off

Host ACK Timeout

You can set a timeout for the length of time the scanner waits for a valid escape
command when using Host Acknowledgment Mode. Set the length (in seconds) for
a timeout by scanning the following bar code, then setting the timeout (from 1-90
seconds) by scanning digits from the
then scanning Save. Default = 10.

Host ACK Responses

Command
[ESC] a,
Orbit 7120plus/7190g User Guide
The scanner reads the code and sends data to the host system. No audible or
visual indication is emitted until the scanner receives an escape command. The
scanner read illumination goes out when there's a successful read.
Scanner operation is suspended until 1) a valid escape string is received from
the host system or 2) the scanner times out.
Once condition 1 or 2 above has been met, the scanner is ready to scan again,
and the process repeats.
Host ACK On
Programming Chart,
Host ACK Timeout
Action
Double beeps to indicate a successful menu change was made.
* Host ACK Off
beginning on page 225,
45