Image Ship - Imgshp - Honeywell ORBIT 7120PLUS User Manual

Hybrid presentation scanner
Table of Contents

Advertisement

U - Update Tries
This sets the maximum number of frames the scanner should take to reach the
Delta for
(Default = 6)
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image. A setting
of 75% means 75% of the pixels are at or below the target white value, and 25% of
the pixels are above the target white value. Altering this setting from the default is
not recommended under normal circumstances. To alter grayscale values,
Target White Value
Example:
Step 2 - Ship a Picture Using IMGSHP

Image Ship - IMGSHP

An image is taken whenever the Image Snap (IMGSNP) command is processed.
The last image is always stored in memory. You can "ship" the image by using the
IMGSHP command.
The image ship commands have many different modifiers that can be used to
change the look of the image output. Modifiers affect the image that is transmit-
ted, but do not affect the image in memory. Any number of modifiers may be
appended to the IMGSHP command.
Example: You can use the following command to snap and ship a bitmap image with gamma
correction and document image filtering: IMGSNP;IMGSHP8F75K26U
Orbit 7120plus/7190g User Guide
Acceptance. Update Tries is only available when using Photo Style (1P).
nU
Range: 0 - 10
should be used. (Default = 50)
n%
Range: 1 - 99
Target Set Point
Percentage at 97%:
Target Set Point
Target Set Point
Percentage at 50%:
Percentage at 40%:
D -
W -