Rs232 Receiver Time-Out; Rs232 Handshaking - Honeywell ORBIT 7120PLUS User Manual

Hybrid presentation scanner
Table of Contents

Advertisement

RS232 Receiver Time-Out

The unit stays awake to receive data until the RS232 Receiver Time-Out expires. A
manual or serial trigger resets the time-out. When an RS232 receiver is sleeping, a
character may be sent to wake up the receiver and reset the time-out. A transaction
on the CTS line will also wake up the receiver. The receiver takes 300 milliseconds
to completely come up. Change the RS232 receiver time-out by scanning the bar
code below, then scanning digits from the inside back cover of this manual, then
scanning Save. The range is 0 to 300 seconds. Default = 0 seconds (no time-out -
always on).

RS232 Handshaking

RS232 Handshaking allows control of data transmission from the scanner using
software commands from the host device. When RTS/CTS is turned Off, no data
flow control is used.
Flow Control, No Timeout: The scanner asserts RTS when it has data to send, and
will wait indefinitely for CTS to be asserted by the host.
Orbit 7120plus/7190g User Guide
7 Data, 2 Stop Parity None
8 Data, 1 Stop, Parity Even
8 Data, 1 Stop, Parity Odd
RS232 Receiver Time-Out
7 Data, 2 Stop, Parity Odd
* 8 Data, 1 Stop, Parity None
8 Data, 1 Stop, Parity Mark
29