Group
10 START/STOP
Settings for
• selecting start/stop/direction signal sources for external control locations EXT1
and EXT2
• selecting sources for external fault reset, run enable and start enable signals
• selecting sources for emergency stop (OFF1 and OFF3)
• selecting source for jogging function activation signal
• enabling the start inhibit function.
See also section
10
10 START/STOP
Firmware block:

DRIVE LOGIC

(10)
This block
• selects the sources for the start/
stop/direction signals for external
control locations EXT1 and EXT2
• selects the sources for external
fault reset, run enable and start
enable signals
• selects the sources for emergency
stop (OFF1 and OFF3)
• selects the source for jogging
activation signal
• enables the start inhibit function.
Jogging
on page 43.
[ In1 ]
[ DI STATUS.0 ]
(2 / 2.01.DI1)
[ FALSE ]
[ In1 ]
[ DI STATUS.0 ]
(2 / 2.01.DI1)
[ FALSE ]
[ FALSE ]
[ DI STATUS.2 ]
(2 / 2.01.DI3)
[ TRUE ]
[ TRUE ]
[ TRUE ]
[ Disabled ]
[ FBA MAIN CW ]
(4 / 2.12)
[ FALSE ]
[ FALSE ]
[ D2D MAIN CW ]
(4 / 2.17)
[ TRUE ]
DRIVE LOGIC
21
TLF10 2 msec
(3)
2.18 D2D FOLLOWER CW
6.01 STATUS WORD 1
6.02 STATUS WORD 2
6.03 SPEED CTRL STAT
6.05 LIMIT WORD 1
6.07 TORQ LIM STATUS
6.09 POS CTRL STATUS
6.10 POS CTRL STATUS2
6.11 POS CORR STATUS
10.01 EXT1 START FUNC
< 10.02 EXT1 START IN1
< 10.03 EXT1 START IN2
10.04 EXT2 START FUNC
< 10.05 EXT2 START IN1
< 10.06 EXT2 START IN2
< 10.07 JOG1 START
< 10.08 FAULT RESET SEL
< 10.09 RUN ENABLE
< 10.10 EM STOP OFF3
< 10.11 EM STOP OFF1
10.12 START INHIBIT
< 10.13 FB CW USED
< 10.14 JOG2 START
< 10.15 JOG ENABLE
< 10.16 D2D CW USED
< 10.17 START ENABLE
Parameters and firmware blocks
73