Comparison - ABB ACSM1 Firmware Manual

Speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

238

Comparison

EQ
(10040)
Illustration
Execution time
Operation
Inputs
Outputs
GE
>=
(10041)
Illustration
Execution time
Operation
Inputs
Outputs
GT
>
(10042)
Illustration
Execution time
Standard function blocks
(DINT)
TLA1 1 msec
IN1
IN2
0.89 µs (when two inputs are used) + 0.43 µs (for every additional input). When all
inputs are used, the execution time is 13.87 µs.
The output (OUT) is 1 if all the connected input values are equal (IN1 = IN2 = ... =
IN32). Otherwise the output is 0.
The input data type and the number of inputs (2...32) are selected by the user.
Input (IN1...IN32): INT, DINT, REAL, REAL24
Output (OUT): Boolean
(DINT)
TLA1 1 msec
IN1
IN2
0.89 µs (when two inputs are used) + 0.43 µs (for every additional input). When all
inputs are used, the execution time is 13.87 µs.
The output (OUT) is 1 if (IN1 > IN2) & (IN2 > IN3) & ... & (IN31 > IN32). Otherwise the
output is 0.
The input data type and the number of inputs (2...32) are selected by the user.
Input (IN1...IN32): INT, DINT, REAL, REAL24
Output (OUT): Boolean
(DINT)
TLA1 1 msec
IN1
IN2
0.89 µs (when two inputs are used) + 0.43 µs (for every additional input). When all
inputs are used, the execution time is 13.87 µs.
EQ
75
(1)
OUT(75)
OUT
GE
76
(1)
OUT(76)
OUT
GT
77
(1)
OUT(77)
OUT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents