ABB ACSM1 Firmware Manual page 202

Speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

202
Code
Alarm
(fieldbus code)
2006
EMERGENCY OFF
(0xF083)
2007
RUN ENABLE
(0xFF54)
2008
ID-RUN
(0xFF84)
2009
EMERGENCY STOP
(0xF081)
2011
BR OVERHEAT
(0x7112)
2012
BC OVERHEAT
(0x7181)
2013
DEVICE OVERTEMP
(0x4210)
2014
INTBOARD OVERTEMP
(0x7182)
2015
BC MOD OVERTEMP
(0x7183)
Fault tracing
Cause
Drive has received emergency
OFF2 command.
No Run enable signal is
received.
Motor identification run is on.
Motor identification is required.
Drive has received emergency
stop command (OFF1/OFF3).
Brake resistor temperature has
exceeded alarm limit defined by
parameter
48.07 BR TEMP
ALARMLIM.
Brake chopper IGBT
temperature has exceeded
internal alarm limit.
Measured drive temperature
has exceeded internal alarm
limit.
Interface board (between power
unit and control unit)
temperature has exceeded
internal alarm limit.
Input bridge or brake chopper
temperature has exceeded
internal alarm limit.
What to do
To restart drive, activate RUN ENABLE signal
(source selected by parameter
ENABLE) and start drive.
Check setting of parameter
ENABLE. Switch signal on (e.g. in the
fieldbus Control Word) or check wiring of
selected source.
This alarm belongs to normal start-up
procedure. Wait until drive indicates that
motor identification is completed.
This alarm belongs to normal start-up
procedure.
Select how motor identification should be
performed, parameter
99.13 IDRUN
Start identification routines by pressing Start
key.
Check that it is safe to continue operation.
Return emergency stop push button to normal
position (or adjust the fieldbus Control Word
accordingly).
Restart drive.
Stop drive. Let resistor cool down.
Check resistor overload protection function
settings, parameters 48.01...48.05.
Check alarm limit setting, parameter 48.07.
Check that braking cycle meets allowed
limits.
Let chopper cool down.
Check resistor overload protection function
settings, parameters 48.01...48.05.
Check that braking cycle meets allowed
limits.
Check that drive supply AC voltage is not
excessive.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
Let drive cool down.
Let drive cool down.
10.09 RUN
10.09 RUN
MODE.