Parrdintr; Parrdptr - ABB ACSM1 Firmware Manual

Speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

Operation
Inputs
Outputs

PARRDINTR

(10101)
Illustration
Execution time
Operation
Inputs
Outputs

PARRDPTR

(10100)
Illustration
Execution time
Reads the value of a parameter (specified by the Group and Index inputs). If the
parameter is a pointer parameter, the Output pin provides the number of the source
parameter instead of its value.
Error codes are indicated by the error output (Error) as follows:
Error code
Description
0
No error
0
Error
See also blocks
PARRDINTR
Parameter group input (Group): DINT
Parameter index input (Index): DINT
Output (Output): DINT
Error output (Error): DINT
PARRDINTR
(BOOL)
TLA1 1 msec
Group
Index
-
Reads the internal (non-scaled) value of a parameter (specified by the Group and Index
inputs). The value is provided by the Output pin.
Error codes are indicated by the error output (Error) as follows:
Error code
Description
0
No error or busy
0
Error
Parameter group (Group): DINT
Parameter index (Index): DINT
Output (Output): Boolean, INT, DINT, REAL, REAL24
Error output (Error): DINT
PARRDPTR
(BOOL)
TLA1 1 msec
Group
Index
-
and PARRDPTR.
73
(1)
Output(73)
Output
Error(73)
Error
74
(1)
Output(74)
Output
Error(74)
Error
285