DINT_TO_BOOL

(10020)
Illustration
Execution time
Operation
Inputs
Outputs
DINT_TO_BOOL
TLA1 1 msec
IN
11.98 µs
The boolean output (OUT1...32) values are formed from the 32-bit integer input (IN)
value.
Example:
IN = 0 111 1111 1111 1111 1111 1111 1111 1100
OUT32...OUT1
SIGN
Input (IN): DINT
Output (OUT1...OUT32): Boolean
Sign output (SIGN): Boolean
83
(1)
OUT1(83)
OUT1
OUT2(83)
OUT2
OUT3(83)
OUT3
OUT4(83)
OUT4
OUT5(83)
OUT5
OUT6(83)
OUT6
OUT7(83)
OUT7
OUT8(83)
OUT8
OUT9(83)
OUT9
OUT10(83)
OUT10
OUT11(83)
OUT11
OUT12(83)
OUT12
OUT13(83)
OUT13
OUT14(83)
OUT14
OUT15(83)
OUT15
OUT16(83)
OUT16
OUT17(83)
OUT17
OUT18(83)
OUT18
OUT19(83)
OUT19
OUT20(83)
OUT20
OUT21(83)
OUT21
OUT22(83)
OUT22
OUT23(83)
OUT23
OUT24(83)
OUT24
OUT25(83)
OUT25
OUT26(83)
OUT26
OUT27(83)
OUT27
OUT28(83)
OUT28
OUT29(83)
OUT29
OUT30(83)
OUT30
OUT31(83)
OUT31
OUT32(83)
OUT32
SIGN (83)
SIGN