Code
Alarm
(fieldbus code)
2042
D2D CONFIG
(0x7583)
2047
SPEED FEEDBACK
(0x8480)
2048
OPTION COMM LOSS
(0x7000)
Cause
The settings of drive-to-drive
link configuration parameters
(group 57) are incompatible.
No speed feedback is received.
Communication between drive
and option module (FEN-xx
and/or FIO-xx) is lost.
What to do
Check the settings of the parameters in group
57 D2D
COMMUNICATION.
Check the settings of the parameters in group
22 SPEED
FEEDBACK.
Check encoder installation. See the
description of fault
0039
(ENCODER1) for
more information.
Check that option modules are properly
connected to Slot 1 and (or) Slot 2.
Check that option modules or Slot 1/2
connectors are not damaged. To determine
whether module or connector is damaged:
Test each module individually in Slot 1 and
Slot 2.