Value pointer: Group and index
32.04 MAXIMUM TORQ REF
Defines the maximum torque reference.
0...1000%
32.05 MINIMUM TORQ REF
Defines the minimum torque reference.
-1000...0%
32.06 LOAD SHARE
Scales the external torque reference to a required level (external torque reference is multiplied by the
selected value).
Note: If local torque reference is used, no load share scaling is applied.
-8...8
32.07 TORQ RAMP UP
Defines the torque reference ramp-up time, i.e. the time for the reference to increase from zero to the
nominal motor torque.
0...60 s
32.08 TORQ RAMP DOWN
Defines the torque reference ramp-down time, i.e. the time for the reference to decrease from the
nominal motor torque to zero.
0...60 s
Parameters and firmware blocks
FW block:
TORQ REF MOD
Maximum torque reference.
FW block:
TORQ REF MOD
Minimum torque reference.
FW block:
TORQ REF MOD
External torque reference multiplier.
FW block:
TORQ REF MOD
Torque reference ramp-up time.
FW block:
TORQ REF MOD
Torque reference ramp-down time.
(see above)
(see above)
(see above)
(see above)
(see above)