2 Installation and commissioning
2.5.8 Connectors on the computer unit
Continued
The service port is configured with a fixed IP-address, which is the same for all
controllers and cannot be changed, and has a DHCP server that automatically
assigns an IP-address to the connected PC.
WAN port
The WAN port is a public network interface to the controller, typically connected
to the factory network with a public IP address provided by the network
administrator.
The WAN port can be configured with fixed IP-address, or DCHP, from the Boot
application on the FlexPendant. By default the IP-address is blank.
Some network services, like FTP and RobotStudio, are enabled by default. Other
services are enabled by the respective RobotWare application.
LAN ports
The LAN 1 port is dedicated for connecting the FlexPendant.
The LAN 2 and LAN 3 ports are intended for connecting network based process
equipment to the controller. For example field buses, cameras, and welding
equipment.
Continues on next page
74
Note
For more information about connecting a PC to the service port, see section
Working online in Operating manual - RobotStudio.
Note
The WAN port cannot use any of the following IP-addresses which are allocated
for other functions on the IRC5 controller:
192.168.125.0 - 255
192.168.126.0 - 255
192.168.127.0 - 255
192.168.128.0 - 255
192.168.129.0 - 255
192.168.130.0 - 255
The WAN port cannot be on a subnet which overlaps with any of the above
reserved IP-addresses. If a subnet mask in the class B range has to be used,
then a private address of class B must be used to avoid any overlapping. Please
contact your local network administrator regarding network overlapping.
See the section about topic Communication in Technical reference
manual - System parameters.
Note
For more information about connecting a PC to the WAN port, see section Working
online in Operating manual - RobotStudio.