4 Repair
4.20 Replacement of brake resistor bleeder for PMC large
Continued
9
Refitting
The following procedure details how to refit the brake resistor bleeder
1
2
3
4
5
Continues on next page
210
Action
Lift and remove the brake resistor bleeder.
Action
Refit the bleeder to the air channel plate.
Tighten the attachment screws for the
brake resistor bleeder.
Guide the brake resistor cables though the
cable gland of the air channel.
Refit the plate on the back of the air chan-
nel.
Refit the air channel.
© Copyright 2007-2018 ABB. All rights reserved.
Note/illustration
xx1100000530
Note/illustration
xx1100000531
Cable gland
Product manual - IRC5 Panel Mounted Controller