4 Repair
4.2 Replacement of panel board
Continued
2
3
4
Refitting
The procedure below details how to refit the panel board unit.
1
2
Continues on next page
148
Action
xx0200000023
WARNING
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the section
The unit is sensitive to ESD on page 32
Disconnect all connectors.
Remove the lower attachment screws, and remove
the Panel Unit.
Action
DANGER
Before commencing any work inside the cabinet,
please observe the safety information in section
Make sure that the main power has been switched
off on page
25.
xx0200000023
WARNING
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the section
The unit is sensitive to ESD on page 32
© Copyright 2007-2018 ABB. All rights reserved.
Note/Illustration
Note
Make a note of any connections.
xx0600003227
A: fixed attachments
B: hole for attachment
screw
Note/Illustration
Product manual - IRC5 Panel Mounted Controller