Installing the modules in a cabinet
The IRC5 Panel Mounted Controller modules should be mounted on a rack system
in a cabinet. The recommended minimum depth of the cabinet is 400 mm for PMC
small and 500 mm for PMC large. The cabinet must fulfill the requirements specified
in
The following procedure details how to install the IRC5 Panel Mounted modules.
1
2
3
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: J
Protection class on page
Action
Fit the module on pre-mounted M5 screws (4 pcs).
Secure the module with new M5 screws (4 pcs).
Fasten the module (M5 screw, 8 pcs)
© Copyright 2007-2018 ABB. All rights reserved.
2 Installation and commissioning
2.4.2 Installation, IRC5 Panel Mounted Controller
48.
Continued
Note/Illustration
xx0600003452
A: M5 screws (4 pcs)
xx0600003453
B: M5 screws (4 pcs)
Tightening torque 4,5 Nm.
57