ECC800 Data Center Controller
User Manual
After the camera NTP synchronization function is enabled, cameras will automatically
time-synchronize from their access servers.
1.
2.
3.
4.
5.
----End

5.9.2 Commissioning IPC6325 Cameras

Prerequisites
For details about how to commission IP cameras and set parameters for them, see the
document delivered or click
If multiple cameras are accessed, retain the connection of one camera and disconnect
connections from other cameras. After commissioning the connected camera, commission
other cameras in the same way.
Context
The current network is configured with an ECC800 and supports the function of DHCP
(Dynamic Host Configuration Protocol). In the network, the IPC6325 camera automatically
obtains an IP address in the same IP address segment as the ECC800 after the ECC800 and
IPC6325 are powered on. Therefore, you need to reset the IPC6325 camera IP address before
commissioning an IPC6325 camera.
Procedure
Step 1 Reset the IPC6325 camera IP address.
Issue 02 (2019-02-28)
Log in to the OMU portal of the VCN as the Admin user.
Choose Maintenance > Unified Configuration.
Select the server that the camera needs to access, set Module name to SCU and
Parameter type to System property, and click Search.
Figure 5-20 Configuring Camera NTP Synchronization
In the search results, click Edit in the row where Parameter Name is NTPIPC and set
Value to 1.
Click Save. After the camera NTP synchronization function is enabled, the camera, after
being connected to the server, will automatically time-synchronize with the server.
Copyright © Huawei Technologies Co., Ltd.