7
MES INTERFACE FUNCTION CONFIGURATION TOOL
7.11.2 Setting items in Communication action (Select/Update/Insert/MultiSe-
lect/Delete)
This section explains the setting items of communication action when selecting Select/
Update/Insert/MultiSelect/Delete in Action type.
7
- 92
7.11 Job Setting - Actions

7.11.2 Setting items in Communication action (Select/Update/Insert/MultiSelect/Delete)

Figure 7.68 [Communication action] dialog box
Table 7.72 Setting items in the [Communication action] dialog box
Item
Action type
Database
Table name
Browse table name
button
*1
DB-tag link settings
Select/Update/Delete
*1
conditions
*1
Select sort settings
*1
Up to 8192 fields can be set in [DB-tag link settings], [Select/Update/Delete conditions] and [Select
sort settings] for each project.
(The setting can be checked on the status bar of [Job settings] or in the [Communication action]
dialog box.)
Select an action type.
Select a database to be accessed.
Set a table name of the database to be accessed.
Browses the table names registered to the set database.
Set assignments between field values and tag component values (or
constant values).
When [Select], [Update], [MultiSelect], or [Delete] is selected for [Action
type], set conditions for the records to be selected, updated, or deleted.
When [Select] or [MultiSelect] is selected for [Action type], set a condition
for sorting selected records.
Description