SYSTEM CONFIGURATION

2.1.3 System configuration for initial setup

This section shows system configurations for initial setup of the MES interface module
using MES Interface Function Configuration Tool.
Remark
Default value of
"MES interface module"
IP ADDRESS
Subnet mask
2
- 3
2.1 System Configuration
2.1.3 System configuration for initial setup
MES interface module
MES interface module
Figure 2.4 System configurations for initial setup of the MES interface module
The following explains the network settings of the configuration computer when
connecting it to the MES interface module on a 1:1 basis.
1
Set the same network address as the one of the MES interface module in the
network settings for the configuration computer.
Set the values to be identical.
Host
Network section
section
192.168.3.
3
255.255.255.
0
Figure 2.5 Network settings for configuration computer
2
Make the network settings of the configuration computer in the [Internet Protocol
(TCP/IP) Properties] dialog box.
®
Example: Microsoft
Figure 2.6 [Internet Protocol (TCP/IP) Properties] dialog box
3
Twisted pair cable
(Crossing cable)
Ethernet
or
Twisted pair cable
(Straight cable)
Ethernet
Hub
Network section
"Configuration computer"
IP ADDRESS
192.168.3.
Subnet mask
255.255.255.
®
XP
Windows
Professional Operating System
Configuration computer
Configuration computer
Set different values.
Host
section
1
0