MES INTERFACE FUNCTION CONFIGURATION TOOL
7.11.2 Setting items in Communication action (Select/Update/Insert/MultiSelect/Delete)
Table 7.78 Values available for substitution
Data type of tag
component
Bit type
ON/OFF is selectable.
Single-precision type
Up to 16 characters
Double-precision type
• Signed decimal notation (Example: -521.98)
Floating-point type
• Signed exponential notation (Example: -5.2198E03)
16-bit BCD type
Unsigned 16-bit BCD notation 0 to 9999 (Example: 1234)
32-bit BCD type
Unsigned 32-bit BCD notation 0 to 99999999 (Example: 12345678)
Up to 32 characters
For characters that can be used for strings, refer to the following.
String
3) Continue this job/Finish this job
• When [Continue this job] is selected.
After executions of exception processing described in the above 1) and 2),
the system continues executions of other actions.
• When [Finish this job] is selected
After executions of exception processing described in the above 1) and 2),
the system forcibly terminates the job without executing other actions.
At this time, update/insert/delete values before execution of the exception
processing are committed, and they are written to relevant tag
components.
(1) When a job is forcibly terminated due to exception processing, an error
occurred during job execution (job cancellation) is not notified.
Section 7.10.5 Setting items for job cancellation
(2) If [Enable DB buffering] is selected for a job, its exception process setting is
disabled.
Section 7.10.4 Setting items in DB Buffering
Values available for substitution
Appendix 2.3 Characters available for character string constants,
etc.
7.11 Job Setting - Actions
1
2
3
4
5
6
7
8
7
- 113