6
FUNCTIONS
(e) Acquiring output arguments or I/O arguments
When the following procedures are called in the stored procedure of SQL Server,
the MES interface module cannot receive the value assigned to the argument as a
execution result of the stored procedure.
• Select, Insert, Update, Delete statement
• Stored procedure including the above
• System stored procedure such as sp_who
Specify "SET NOCOUNT ON" before calling the above procedures in the stored
procedure for the MES interface module to receive the values assigned to
arguments.
6.1.7 Stored procedure call function (Communication action)