Tag Function - Mitsubishi Electric Melsec Q Series User Manual

Programmable contoller mes interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

6
FUNCTIONS

6.1.3 Tag function

The tag function collects device data of the programmable controller CPUs on the network
in units of tags.
By allocating database fields to tag components, the DB interface function enables the
following.
• Database value reading/writing
• Reading/writing of programmable controller CPU device data specified with tag
For the tag function setting, refer to the following:
Section 7.8 Device Tag Setting
components
Programmable
controller CPU
CPU1
Device
Read
D1000
D2000
Write
D2001
(1) Values assigned to tag components by the job are written to a programmable
controller CPU after all actions of the job are completed. Since these values
are occasionally written in two or more sequence scans, values from the
sequence program need to be referred after all data are written.
Use the handshake operation to run the sequence program with the
completion of writing all data.
Section 7.10.2 (8) Handshake operation
(2) For the tags for which [Enhance sampling efficiency] is selected, the tag data
can be read out at high speed when they are collected and when handshake
operation is performed.
MES interface module
Device tag name: Process1
Component name CPU name
Work_No
CPU1
Parameter
CPU1
Figure 6.3 Tag function
6.1 DB Interface Function
6.1.3 Tag function
Device
Data type
Single
D1000
Double
D2000
6
- 4
1
2
3
4
5
6
7
8