10
TROUBLESHOOTING
Error code
0x20C00009
0x20C0000A
0x20C0000B
to
0x20C0000D
0x20C0000E
0x20C0000F
0x2FE00010
Table 10.7 Access log output error list of DB Connection Service
Error description and cause
Failed to execute SQL when acquiring field names
from the database
System error
The database type set for the DB server setting is
different from the actual database type.
System error
*1
[Database error number] and [Database error message] are output to the space after Database
Message in the access log of DB Connection Service.
For the output log format, refer to the following.
Section 8.8.1 Access log
• Set the database type of the DB server setting
correctly with the MES Interface Function
Configuration Tool.
• Check if there is any problem in the connection
route.
• Please consult your local Mitsubishi
representative.
• Set the database type of the DB server setting
correctly with the MES Interface Function
Configuration Tool.
• Please consult your local Mitsubishi
representative.
10.2 Error Code List
10.2.2 Error codes of DB Connection Service
(From the previous page)
Corrective action
10