TE01: Installation and activation of loadable compile cycles
9.6 Creating alarm texts
9.6.3
Creating alarm texts with HMI Embedded
The following alarms should be added to the alarm texts of the technology functions:
075999 0 0 "Channel %1 Sentence %2 Call parameter is invalid"
Proceed as follows
1. Create the required language-dependent sub-directories in the "/oem/sinumerik/hmi/lng"
directory, e.g.:
"deu" for German
"eng" for English
2. Create the "alc.txt" text file in the language directories.
3. Insert the new alarm text in the language-dependent text files, e.g.:
075999 0 0 "Channel %1 Sentence %2 Call parameter is invalid"
in the text file in German.
4. Restart HMI Embedded.
For more information about creating alarm texts with HMI Embedded, please refer to:
References:
/IAM/ SINUMERIK 840D sl/840Di sl/840D/840Di Commissioning CNC Part 2 (HMI);
Commissioning HMI Embedded (IM2), Chapter: Creating In-House Texts
446
Function Manual, 09/2011, 6FC5397-2BP40-2BA0
Special Functions