M3: Coupled axes
5.2 Curve tables
Figure 5-3
5.2.7
Activation/deactivation
Activation
The coupling of real axes to a curve table is activated through this command:
LEADON (<Following axis>, <Leading axis>, <n>)
with <n> =Number of the curve table
Activation is possible:
•
In the part program
•
in the definition of a synchronous action
Example:
...
N1000 LEADON(A,X,3)
...
228
Determining the minimum and maximum values of the table
; Axis A follows the master value X according to the rule
of motions defined in Curve Table No. 3
Function Manual, 09/2011, 6FC5397-2BP40-2BA0
Special Functions