9.1
Loading compile cycles
9.1.1
Loading a compile cycle with HMI sl
Precondition
•
The compile cycle to be transferred to the control must be saved on a storage medium
which can be directly connected to the control, such as a USB-FlashDrive.
•
Access authorization of protection level 1 "Machine manufacturer" (default password
"SUNRISE") must be available.
•
If there are no cursor keys on the operator panel, a mouse or keyboard must be connected
in order to perform the operator actions.
Execution
Perform the following steps to load a compile cycle from a USB-FlashDrive, for example:
1. Insert the USB-FlashDrive in the USB interface on the front of the operator panel.
2. At the user interface, change into the "System data" area:
Horizontal softkey bar: "Operating area switchover" > "Commissioning" > "System data"
3. Open the USB-FlashDrive: Directory "USB" (keyboard: "Enter" key).
4. Select the compile cycle and copy it:
Vertical softkey bar: "Copy"
5. Within the "System data" area, switch into the directory "NC data" > "Compile cycles" and
insert the compile cycle there:
Vertical softkey bar: "Insert"
6. Initiate an NCK reset to activate the compile cycle:
Horizontal softkey bar: "Operating area switchover" > "Commissioning" > "Machine data"
Vertical softkey bar: "Reset (po)"
Special Functions
Function Manual, 09/2011, 6FC5397-2BP40-2BA0
TE01: Installation and activation of loadable compile cycles
9.1 Loading compile cycles
435