Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 556

Process control function blocks
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Offset
Label
+4
b0
TOI
b1
TRIPI
b2
DVLI
b3
DPNI
b4
DPPI
b5
PLI
b6
PHI
b7
LLI
b8
HHI
b9
SEI
bF
ERRI
+5
b0
TOL
b1
TRIPL
b2
DVLL
b3
DPNL
b4
DPPL
b5
PLL
b6
PHL
b7
LLL
b8
HHL
b9
SENL
bE
SPL
+6
CTNO
+7
CTFN
+8
FPNO
+10
PV
+11
+12
b0
VOUT_OPEN
b1
VOUT_CLOSE
+14
SVC
+15
APPX
554
Appendix 1 Tag Data List
Data
Setting/
Initial
type
Storage range
value
Low
High
limit
limit
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
INT
0
32
0
WORD
0
H0002
H0000
INT
1
50
1
REAL
0
100
0.0
BOOL
FALSE
TRUE
FALSE
BOOL
FALSE
TRUE
FALSE
REAL
0
100
0.0
Number
Unit
Application
of digits
after the
decimal
point
Disable Time-out
Alarm
Disable Trip Alarm
Disable Large
Deviation Alarm
Disable Negative
Variation Rate Alarm
Disable Positive
Variation Rate Alarm
Disable Input Low
Limit Alarm
Disable Input High
Limit Alarm
Disable Input Low Low
Limit Alarm
Disable Input High
High Limit Alarm
Disable Sensor Error
Alarm
Disable All Alarms
Alarm Level of Time-
out Alarm
Alarm Level of Trip
Alarm
Alarm Level of Large
Deviation Alarm
Alarm Level of
Negative Variation
Rate Alarm
Alarm Level of
Positive Variation Rate
Alarm
Alarm Level of Input
Low Limit Alarm
Alarm Level of Input
High Limit Alarm
Alarm Level of Input
Low Low Limit Alarm
Alarm Level of Input
High High Limit Alarm
Alarm Level of Sensor
Error Alarm
Alarm Level of Stop
Alarm
Lockout Tag No.
Lockout Tag Function
Faceplate Display
Pattern
1
%
Motor Valve Opening
Output of Open
Command Signal
Output of Close
Command Signal
1
%
Setting Value of Valve
Opening (Current)
Storage
Tag access
FB
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
User
Common
System
System
User
System
System
System
System