Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 489

Process control function blocks
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Setting data
■Input/output variable
Variable
Description
name
MSGIN1
Message 1 input signal
MSGIN2
Message 2 input signal
MSGIN3
Message 3 input signal
MSGIN4
Message 4 input signal
MSGIN5
Message 5 input signal
MSGIN6
Message 6 input signal
MSGIN7
Message 7 input signal
MSGIN8
Message 8 input signal
*1 The default value is FALSE.
■Tag data
For details on tag data that is read or written with this tag FB, refer to the following.
Page 577 MSG
Processing details
■Message input processing
This function block displays the messages for the input pins MSGIN1 to MSGIN8 to which TRUE is input on the "Event List"
window of the PX Developer monitor tool.
For the operating method of PX Developer monitor tool, refer to the following.
 PX Developer Version 1 Operating Manual (Monitor Tool)
Operation error
There is no operation error.
Recommended
Type
range
TRUE: Detected
Input variable
*1
FALSE: Reset
TRUE: Detected
Input variable
*1
FALSE: Reset
TRUE: Detected
Input variable
*1
FALSE: Reset
TRUE: Detected
Input variable
*1
FALSE: Reset
TRUE: Detected
Input variable
*1
FALSE: Reset
TRUE: Detected
Input variable
*1
FALSE: Reset
TRUE: Detected
Input variable
*1
FALSE: Reset
TRUE: Detected
Input variable
*1
FALSE: Reset
15 MESSAGE TAG
15.1 Message (M+M_MESSAGE)
Data type
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
15
487